ASTM-A967 | Standard Specification for Chemical Passivation Treatments

Notes. Claudia's Notes: Changes to the new 2013 Edition of A967/A967M can be found in the following areas: Section 1.5 (changed to combined Metric/US units), Revised Section 4.1 and added Section 4.3, Added Notes 2 and 3 to Sections 6 and 7, Revised Section 13.3, Combined Sections 14 through 19 into a new Section 14, Revised Section 22.1 (Now …

Passivation | ASTM A967 | AMS 2700 | ASTM F86 | QQ-P-35 …

ASTM A967/A967M-17 (CITRIC ACID) 7.1.1.1 Citric 1—The solution shall contain 4 to 10 weight percent of citric acid. The parts shall be immersed for a minimum of 4 min at a temperature in the range from 60 to 70°C [140 to 160°F] 7.1.1.2 Citric 2—The solution shall contain 4 to 10 weight percent of citric acid.

ASTM A 967/A967M : 2017 | Chemical Passivation …

ASTM A 967/A967M : 2017. Current. Add to Watchlist. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Available format (s): Hardcopy, PDF. Language (s): English. Published date: 07-01-2017. Publisher: American Society for Testing and Materials.

ASTM A967 vs. AMS 2700? Which is the right passivation spec?

A. As Ken says, ASTM A380 [affil link] should not be used as a passivation specification, and QQ-P-35 has been canceled. The 3 consensus specifications used at this time, and that should be used for all specifications of passivation are: ASTM F86 [affil link] for Orthopedic implants, AMS2700 [affil link] for Aerospace, ASTM A967 [affil link ...

Chemical Passivation Treatments for Stainless Steel Parts1

Designation: A967/A967M − 17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts1 This standard is issued under the fixed …

WK84146 Revision of A967/A967M-17 Standard

Revision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. A967 was developed for replacement of Mil QQ-P 35. As part of the development, the word "dissolved" appears to be accidental dropped in para. 7.2. for the description of clean water. ... ASTM offers descriptions of …

Guide to Passivation Treatments [Specific Content]

The standard ASTM-A967 covers several different types of chemical passivation treatments for stainless steel parts. Then we find that the classification is similar but a little different in details than that in AMS2700B. 1. Treatments in Nitric Acid Solutions. There are types of Nitric 1, Nitric 2, Nitric 3, Nitric 41, Nitric 5. ...

Standard Test Method for Compressive Strength of …

Scope. 1.1 This test method covers determination of compressive strength of cylindrical concrete specimens such as molded cylinders and drilled cores. It is limited to concrete having a density in excess of 800 kg/m 3 [50 lb/ft 3 ]. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard.

ASTM A967 and AMS 2700 Standards for Passivation

ASTM A967. General industries use this standard to describe and control the passivation of stainless steel. Passivation is a process of making stainless steel more stainless than it would be if left alone. It is based on using an acid (nitric or citric) under highly controlled conditions to remove free iron particles from the surface and to help form a metal oxide …

A380/A380M Standard Practice for Cleaning

1.1 This practice covers recommendations and precautions for cleaning, descaling, and passivating of new stainless steel parts, assemblies, equipment, and installed systems. These recommendations are presented as procedures for guidance when it is recognized that for a particular service it is desired to remove surface contaminants that …

ASTM A967/A967M-17

ASTM International [astm] PDF Price. $57.00. Add to cart Not a Member? Find out how to get ANSI Member Discount Others Also Bought. ASTM A380/A380M-17. Standard Practice for Cleaning, Descaling, and …

Chemical Passivation Treatments for Stainless Steel Parts

Scope. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and …

ASTM International

ASTM A967/A967M-13 February 15, 2013 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and...

Passivation of Corrosion Resistant Steels

Both AMS 2700 and ASTM A967 base their nitric acid passivation methods on using 42° Baume nitric acid. The Baume scale is a measurement of specific gravity. Positive degrees of Baume indicate chemicals or solutions denser than water. 42° Baume nitric acid corresponds to a 1.4 specific gravity solution of nitric acid that is roughly 67% …

Understanding QQ-P-35: The Predecessor of ASTM A967 …

For example, ASTM A967 contains more options for passivation verification tests while AMS2700 provides more guidance on sampling large batches of components for testing and inspection after passivation. As the most direct linear descendant of QQ-P-35, AMS 2700 naturally shows its "heritage". QQ-P-35 types II, VI, VII and VIII are equivalent ...

AMS 2700: Which Type with Which Grade?

With that roman numeral type reccomendation from QQ-P-35 in hand, you can make a corresponding AMS 2700 (Method 1) callout by changing the roman numberal to the corresponding arabic numneral as shown below: QQ-P-35, Type II: AMS 2700, Method 1, Type 2. QQ-P-35, Type VI: AMS 2700, Method 1, Type 6.

(번역본)ASTM A967-01 Standard Specification for Chemical Passivation

ASTM A967-01 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts . 1. Scope(범위) * Stainless Steel 의 descaling, cleaning, passivation 에 대한 권고 및 예방책을 제시한다.

Passivation of Stainless Steels Using Electropolishing1

2.1 ASTM Standards:2 A380/A380M Practice for Cleaning, Descaling, and Passi-vation of Stainless Steel Parts, Equipment, and Systems A967/A967M Specification for Chemical Passivation Treat-ments for Stainless Steel Parts B117 Practice for Operating Salt Spray (Fog) Apparatus B322 Guide for Cleaning Metals Prior to Electroplating

· ASTM A 967-05 SPECIFICATIONS · QQ-P-35C/AMS-QQ …

35A, AMS 2700C, ASTM A 967-05 and ASTM A 380-06 standards. Passivation alone will not remove heavy adherent oxide films created from heat treatment, welding, hot-forming and other high-temperature operations. Therefore AST uses different types of pickling acids designed to remove these films prior to the Passivation of the parts.

ASSIST-QuickSearch Document Details

Chemical Passivation Treatments for Stainless Steel Parts (Replaced by ASTM-A967/A967M) Scope: This specification covers several different types of chemical …

WK77171 Revision of A967/A967M-17 Standard

Revision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. ... ASTM Standard C33, 2003e1, "Specification for Concrete Aggregates," ASTM International, West Conshohocken, PA, 2003, DOI: 10.1520/C0033 ...

ASTM A967/A967M

:ASTM A967/A967M タイトル:Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts ステンレスのパッシベーションの は、ステンレスのについてしたものである。をいた、クエンを ...

ASTM A967 vs ASTM A380

ASTM A967 and ASTM A380 have similar mechanical properties. Both materials have a yield strength of 205 MPa and a tensile strength of 520 MPa. The main difference is that ASTM A967 has a higher elongation at break (10%) than ASTM A380 (8%). This means that ASTM A967 is more ductile than ASTM A380 and is better suited …

What is ASTM A967?

1. Passivation Process: ASTM A967 defines the passivation process as the removal of free iron or other foreign matter from the surface of stainless steel by means of a chemical treatment. This treatment encourages the formation of a passive oxide layer, strengthening the steel's resistance to corrosion. 2.

Stainless Steel Passivation Services

Delstar is the industry leader in stainless steel passivation services, delivering the highest quality of passivated products to our customers since 2002. Here at Delstar Metal Finishing, we offer stainless steel passivation services with a focus on ASTM A967, ASTM A380, ASTM B912, and QQP35C specifications. Call or contact us today to speak to ...

Monitoring Passivation on Stainless Steel with Open …

Stainless Steel Parts, Equipment and Systems. ASTM A967 Standard provides tests with acceptance criteria to demonstrate that the passivation procedures have been successful. As per ASTM International Standards; "passivation testing is the process by which stainless steel will spontaneously form a chemically inactive surface when exposed to ...

astm a 967 passivation

6.1 Passivation Treatment:6.1.1 Stainless steel parts shall be treated in one of the. following aqueous solutions and maintained within the speci-fied temperature range for the specified time. 6.1.1.1 Nitric 1—The solution shall contain 20 to 25 volumepercent of nitric acid and 2.5 6 0.5 weight percent of sodium.

ASTM A967/A967M-17

Full Description. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. It includes several alternative tests, with acceptance criteria, for confirmation of effectiveness of ...

ステンレスのパッシベーション

メーカーにとって、astm a967 や ams 2700 などのは、ステンレスをするためにもにされるをしています。 astm a967 でべられているように、パッシベーションは、やそののをしながら、をむ ...

Passivation of Aerospace Stainless Steel Parts with Citric …

ASTM B 117 salt spray testing for 2 to 3 hours, and then evaluated for signs of red rust. Red rust is considered a failure for passivation. In addition, the stainless steel test specimens were also examined for signs of IGA (intergranular attack) and pitting after being treated in the optimized nitric, optimized citric acid, and 3

Norme ASTM A967/A967M-17

Normes remplacées (1) ASTM A967/A967M-13. février 2013. Norme Annulée. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning ...

What is Passivation? How Does Stainless Steel Passivation …

ASTM A380: Finishes for Ground Based Electronic Equipment: Table IV, Finish number E300; MIL-DTL-5002: ASTM A967 AMS 2700: Surface Treatments and Inorganic Coatings For Metal Surfaces of Weapons Systems: Section 3.8.6; MIL-STD-171: ASTM A967 AMS 2700 ASTM A380: Finishing of Metal and Wood Surfaces: Section 5.1.4.2; Table V, …